Beer Cooler Repair
in Longview, TX

A draft system that pours foam is usually described as a beer problem and is almost always a temperature problem. Beer that warms even a few degrees between the keg and the faucet releases dissolved carbon dioxide, and what comes out of the tap is foam. Every inch of that foam is product you bought and cannot sell.

  • Keg & Walk-In Beer Coolers
  • Draft Line Temperature
  • Foaming Diagnosed Properly
  • 24/7 for Bars & Restaurants

Napps Refrigeration — Longview & East Texas since 1957

24/7 Emergency Refrigeration
Licensed & Insured — TACLA 72668C
🏢Commercial Specialists Since 1957
💳Upfront Flat-Rate Pricing

Beer Cooler & Draft Cooling Services

The refrigeration side of a draft system — the part that decides whether what you pour is beer or foam.

🍺

Keg & Beer Coolers

Reach-in keg boxes and dedicated beer walk-ins. Holding steady temperature matters more here than in almost any other refrigerated space.

  • Keg Box Repair
  • Beer Walk-Ins
  • Steady Temperature
  • Fast Response
Walk-In Coolers →
🌡️

Temperature Problems

Beer wants a narrow and consistent range. A cooler that drifts, or one where temperature varies across the box, causes foaming at the tap.

  • Drift & Inconsistency
  • Uneven Box Temperature
  • Airflow Problems
  • Thermostat & Controls
Refrigeration Services →
❄️

Frozen or Over-Cold Beer

The opposite problem and just as costly. Beer near freezing pours flat and cloudy, and a frozen keg line is a service stoppage.

  • Over-Cooling
  • Frozen Lines
  • Control Faults
  • Airflow Distribution
Refrigeration Services →
🚿

Draft Line Cooling

Glycol chillers and forced-air cooled trunk lines. Beer that is correctly chilled in the box and warms on the way to the tap still pours foam.

  • Glycol Chiller Service
  • Trunk Line Cooling
  • Warm Spots Located
  • Long Runs
Commercial HVAC →
🚪

Doors, Gaskets & Seals

Behind a bar, cooler doors get opened constantly all night. Gaskets and hinges wear far faster here than on kitchen equipment.

  • High Door Cycle Count
  • Gasket Replacement
  • Hinges & Closers
  • Cheap Preventive Item
Walk-In Coolers →
🛡️

Preventive Maintenance

Scheduled service before the weekend rather than during it. Bar equipment fails on Friday night with remarkable consistency.

  • Scheduled Servicing
  • Coil Cleaning
  • Before Busy Periods
  • Prevents Weekend Failures
Commercial Services →

Temperature and Draft Beer

Foaming is one of the most common complaints in a bar and one of the most consistently misdiagnosed.

Why warm beer foams

Beer holds dissolved carbon dioxide, and how much it can hold depends on temperature and pressure. Warm it up and the beer can no longer hold that gas in solution, so it comes out — which is exactly what foam is. Even a few degrees of warming between the keg and the faucet is enough to turn a clean pour into a glass of head. This is why draft problems are so often a refrigeration issue rather than a dispensing one.

Refrigeration Services →

It is not enough for the keg cooler to be at the right temperature — the beer has to stay there the whole way to the tap. On any run of more than a few feet the line needs active cooling, either glycol or forced air. A failed chiller, a gap in the insulation, or a section of line that has come away from the cooling bundle creates a warm spot, and beer foams at that point regardless of how cold the box is.

Commercial HVAC →

Over-cooling is less discussed and just as costly. Beer approaching freezing pours cloudy and flat, loses carbonation character, and in a bad case the line or the keg itself freezes and service stops entirely. A cooler that has drifted cold is as much a fault as one that has drifted warm, and it is often a control or airflow distribution problem rather than a thermostat setting.

Refrigeration Services →

We would rather tell you that than sell you a repair. Foaming can also come from incorrect gas pressure, the wrong gas blend for the line run, dirty lines, worn faucet washers, or a keg that was jostled recently. What we can do is establish whether temperature is in range from keg to tap — and if it is, tell you plainly that the problem is on the dispensing side rather than ours.

Commercial Services →

Foaming — Where to Look

We confirm the temperature side; some causes are dispensing.

Cause Refrigeration? Symptom
Beer cooler too warm Yes Foaming worsens through the night
Warm spot in the trunk line Yes First pour foams, then settles
Glycol chiller failure Yes All taps foaming
Cooler too cold Yes Flat, cloudy pour or frozen line
Gas pressure or blend No — dispensing Consistent foaming at correct temperature
Dirty lines or worn washers No — dispensing Off flavours, uneven pour

How a Beer Cooler Call Works

Measure from the keg to the tap, then fix what is actually out of range.

1
Symptom and Timing

When it foams matters — all night, only at open, or worse as service goes on. Each points somewhere different.

2
Measure the Whole Run

Box temperature, line temperature and temperature at the faucet. Foaming is usually where those three disagree.

3
Repair the Cooling Side

Flat rate, agreed first, whether it is the cooler, the chiller or a warm section of line.

4
Honest Handover

If temperature is correct throughout and it still foams, we will tell you the problem is on the dispensing side.

Signs Your Beer Cooling Needs Attention

In a bar these show up as wasted product long before anyone calls it a refrigeration fault.

🫧
Foaming that gets worse through the night The classic signature of a cooler struggling as ambient temperature and door openings accumulate.
🍺
The first pour foams, then settles Usually a warm spot in the line rather than the cooler. The warm beer clears and the properly chilled beer follows.
☁️
Cloudy or flat beer Often over-cooling rather than under. Beer close to freezing loses condition and pours poorly.
🧊
Ice anywhere in the box or on the lines Either a defrost problem or over-cooling. Frozen lines stop service entirely.
⏱️
The cooler running constantly Struggling to hold range. Usually a dirty condenser, a worn gasket or a refrigerant issue.
🚪
Door not sealing behind the bar Bar cooler doors cycle constantly all night. Gaskets wear out here faster than anywhere else in the building.

What We Find Most Often

🌫️
Dirty condenser coils Behind a bar they collect dust and airborne residue quickly, and the unit stops being able to reject heat.
🚪
Worn door gaskets Very high door cycle counts mean bar cooler gaskets are a consumable rather than a permanent fitting.
🧊
Glycol chiller faults Beer correctly chilled in the box, warming on the way to the tap. Every tap foams and nobody suspects the cooler.
🌡️
Control and thermostat drift A box slowly running warmer or colder than its setting, which nobody notices until the pours change.

Why Longview Bars Call Napps

We measure the whole run, and we tell you when the problem is not ours.

  • 📏
    We Measure Keg to Tap Foaming is a temperature problem somewhere along the run. Measuring only the box misses most of them.
  • 🤝
    We Say When It Is Dispensing If temperature is correct throughout, the problem is gas, lines or faucets — and we will tell you rather than replace parts.
  • ⏱️
    24/7, Including Friday Night Bar equipment fails at the worst possible time with impressive reliability. We answer then.
  • 🏢
    Commercial Since 1957 Sixty-five years of East Texas hospitality equipment, with refrigeration and HVAC under one roof.
TACLA 72668C EPA 608 Certified NATE Certified ACCA Member Since 1957
65+
Years Serving East TX
24/7
Emergency Availability
★ 4.8
From 229 Google Reviews
2
TX Licences — HVAC & Plumbing
📅 Call 903-758-6482

Or call 903-758-6482 — available 24/7

Real Reviews from Real Napps Customers

4.8 out of 5 · 229 Google reviews

These come straight from our Google Business Profile — unedited, and updated automatically as new reviews come in.

Beer Cooler & Draft Questions

What bars and restaurants ask about draft cooling.

Why is my draft beer foaming?

Most often temperature. Beer holds carbon dioxide in solution, and warming it even a few degrees releases that gas — which is what foam is. The warming can be in the cooler itself or at a warm spot along the line to the tap. Other causes exist on the dispensing side, such as gas pressure or dirty lines, but temperature is where we would look first and where the answer usually is.

Generally around 36 to 38 degrees, though the important part is consistency and that the temperature is maintained the whole way to the tap rather than just in the box. A cooler holding perfectly at 38 with a warm section of trunk line will still pour foam, because the beer warms on its way. That is why we measure at the keg, along the line and at the faucet.

Yes, and it is a genuine and under-recognised problem. Beer approaching freezing pours cloudy and flat and loses its carbonation character, and in the worst case the line or the keg freezes and service stops. A cooler that has drifted cold is as much a fault as one that has drifted warm, and it is usually a control or airflow distribution issue rather than someone setting it wrong.

We handle the refrigeration side — the cooler, the glycol chiller and the cooling of the trunk line. Line cleaning and the dispensing components such as gas, regulators and faucets are typically handled by a draft service specialist or your distributor. What we will do is establish definitively whether temperature is in range throughout, so you know which conversation to have.

Around the clock, and we are conscious that bar equipment has a habit of failing on a Friday evening. Our line is answered by a person at any hour and beer cooler failures are dispatched with the same urgency as any other refrigeration call, because product at risk is product at risk.

At least twice a year, and ideally scheduled ahead of your busy season rather than during it. Behind a bar the two items that matter most are condenser coil cleaning and door gaskets, because the coils collect residue quickly and the doors cycle far more than kitchen equipment. Both are inexpensive on a schedule and expensive as an emergency.

Draft Pouring Foam? Call 903-758-6482.

We measure from keg to tap — and tell you honestly when the problem is not the cooling.

Request Beer Cooler Service

Tell us whether all taps or just some are affected, and whether it is worse at opening or later in the night. Both narrow it considerably.

  • 📞
    24/7 Emergency Line 903-758-6482
  • 📍
    Office Location 1003 West Cotton St., Longview, TX 75604
  • Emergency Service Available 24 hours a day, 7 days a week
  • 💳
    Financing Available Financing available on commercial refrigeration replacement